About Muhammad Aamir:
I am Muhammad Aamir, i have done DAE Electrical and i have 12 years of UAE experience
Experience
1. Worked as an Electrical and Electronic Supervisor, Sharjah UAE Container Terminal
Gulftainer - (16th July 2010 - 10 July 2020).
▪ Experienced in working at other stations of the Gulftainer Company Ltd., namely
Khorfakhan port in Sharjah port and Umm Qasr port, Iraq.
▪ Responsible for supervising technicians’ activities within the container terminal and
provide technical support to all technicians personally, with a focus towards crane
maintenance.
▪ Ordering spare parts from different suppliers by SAP software, E-mail and on phone.
▪ Technical knowledge and experience in testing, troubleshooting/fault isolation and
repair/overhauling of heavy machinery such as 2*Gottwald Mobile Harbour Cranes, 22 *
Quay Crane Liebherr, and 24 RTG (Rubber Tyer Gantry).
▪ Routine technical activities include replacing faulty drives, fault isolation on 3-phase
power systems, fault isolation on 110v, 24v control circuits, replacement of faulty
contactors, TACHO Generators, ETS, reverse power protection, relays, switchgears, DC
breakers, rectifiers and transformers, and adjustment of settings on frequency drives.
▪ Experience in automation, Programmable Logic Controller (PLC) software and hardware
devices like SIMENS SimaFlexi Soft, Step 7-300, Step5 of Siemens Germany,
CODESYS (Controlled Development System), WINCC, QUICK PIC of LIEBBHERR
Ireland and their inter bus connections.
Worked on the latest Mitsubishi cranes modified by PORTECH Engineers, with latest
PLC Step 7-400.
▪ Inspection and maintenance of sensors like proximity, safety limit, coolant, temperature
and emergency switches.
2. O & M Asst. Engineer, Vital Tech Engineering & Services - (July 2009 – Feb 2010)
▪ Worked with Vital tech as an Asst. Electrical Engineer at O & M department, with
experience focused on telecommunication industry
Areas of responsibility:
▪ Alcatel Lucent GSM/DCS BTS Sites
▪ Alcatel Lucent PDH/SDH Microwave Links
▪ Ericsson GSM equipment
▪ NEC PDH/SDH Microwave (MW) links
▪ Preventive maintenance of MW links
▪ Patching of E1s for site transmission. Flexi Soft
▪ Troubleshooting of Emerson Power Rectifier System
▪ Optical fiber patching for STM-1 Connectivity
▪ Installation, preventive maintenance and Troubleshooting of Diesel Generators, AC
▪ Installation of ATS panel and Repairing of ATS switches
▪ Installation of LVDB, Battery banks and Rectifiers (Emerson and ZTE)
3. Worked with United Human Resource Services as an Account Assistant, - (June
2008 - July 2009)
Job Responsibilities:
• I help to keep maintain accurate records of accounts receivable, accounts payable,
inventory, payroll and other financial data.
• We were preparing and issues invoices and credit memos, applies cash receipts,
reconciles company revenue, monitors and follows up on outstanding account
balances and generates financial reports.
• Printing and E-mail vendor checks and balance related statements, resolve purchase
order problems and refer accounts to collections.
• We solved customer issues, and performed general office tasks, such as answering the
phone, typing letters and filing.
4. Senior Power Technician, Huawei Technologies Pakistan - (Jan 2008 – June 2008)
▪ Worked as a Senior Power Technician at Huawei Technologies Pakistan in the
operations and maintenance department
▪ Travel based responsibilities for maintenance at various sites, such as Karachi, Lahore,
Islamabad, Peshawar.
Education
Diploma of Associate Engineering in Electrical technology (2004-2007)
from NWFF Board of Technical Education Peshawar, Pakistan (Degree attested from
Pakistan and UAE embassy).